The water circulation faults of natural circulation boilers mainly include circulation stagnation, circulation backflow, and membrane boiling.
The influencing factors include:
(1) Internal factors, such as thermal deviation of the water-cooled wall, cause stagnation or backflow of water circulation in individual pipes; Poor water quality leads to scaling and corrosion inside the pipes; Excessive heat load on the water-cooled wall causes film boiling near the inner wall of the tube; The low water level in the steam drum causes insufficient circulation flow, and even leads to "dry boiling".
(2) External factors include high-temperature corrosion of the pipe wall by flue gas, erosion of the pipe wall by ash and slag, and wear of the pipe wall by ash laden airflow.
1. The boiler circulating pump trips due to poor lubrication, mechanical failure, power interruption, or electrical malfunction. The interruption of the flow rate of the boiler circulating pump will cause the danger of dry burning of the radiation section coil, so it should be stopped immediately and reported to the dispatch immediately; Immediately cut off the fuel gas urgently.
2. The inlet filter of the boiler circulating pump is blocked. If the filter of the circulation pump is blocked, the standby pump should be immediately started to restore the circulation flow.
3. The reflux valve of the boiler circulation pump is too open. If the reflux valve of the circulation pump is opened too wide, it should be immediately reduced to restore the circulation volume.
Additional Information:
Precautions for Dalian pump accessories:
1. Please follow the product installation and use instructions for the specific operation of the boiler to ensure the safety of operators and equipment.
2. Before starting up, check if there are any abnormal conditions in the power supply, voltage, and water source. Close the drain valve and open the water supply valve. Check if the water pump is stuck. If the water pump is stuck, remove the fan cover and rotate the motor shaft to a flexible state to start up.
3. When repairing boilers or replacing parts, please cut off the power or use safe voltage to avoid danger caused by live work.
4. The electrical control box, water pump, blower, induced draft fan motor and other parts should be protected from moisture and water to prevent burning. The boiler room should be kept clean.