Chemical pumps can be divided into stainless steel chemical pumps, plastic chemical pumps, polyphenylene sulfide chemical pumps, electric chemical pumps, multi-stage pumps, and pneumatic chemical pumps. The advantages of Dalian Chemical Pump Accessories include a series of products with reasonable layout of water conservancy engineering characteristics, wide selection range for customers, convenient maintenance, efficiency, and suction range. It is commonly used in industrial production, urban water supply and drainage pipelines, and can also be used for irrigation in fields and plantations, for transporting cold water or other liquids with similar physical properties to cold water.

Maintenance methods for chemical pumps:
one
Close the shut-off valve, inlet and outlet pressure gauges, and inlet negative pressure gauge of the outlet circuit tightly.
two
Add lubricating car oil to the body of the rolling bearing, and observe that the oil level should be at the bottom axis of the oil gauge. The lubricating grease should be immediately replaced or filled.
three
Twist open the screw plug of the water intake channel of the chemical pump casing and inject grout into the water intake channel (or grout).
four
Check if there is any looseness in the chemical pump pipeline and joints. Skilled in rotating chemical pumps, free trial to see if chemical pumps are flexible.
five
Electric motor, free trial to see if the motor is converted properly.
six
Start the motor, and when the chemical pump is running normally, turn on the inlet and outlet pressure gauges and the inlet vacuum pump to see if they indicate a moderate working pressure. Then slowly open the shut-off valve and check the motor load condition at the same time.
seven
Manipulate the total flow rate and pump head of the chemical pump as much as possible within the range indicated on the signboard to ensure that the chemical pump operates at the efficiency point, in order to achieve significant energy-saving effects.
eight
During the entire operation of chemical pumps, the temperature of the rolling bearings should not exceed the natural ambient temperature of 35C, and the upper limit temperature should not exceed 80C.
nine
If any abnormal noise is detected in the chemical pump, it should be stopped immediately to check the cause.
ten
When the chemical pump needs to be stopped, first turn off the shut-off valve and pressure gauge, and then terminate the motor.
eleven
Within one month of operation, the chemical pump needs to remove and replace the lubricating grease after 100 hours, and then change the oil every 500 hours thereafter.
twelve
Regularly adjust the sealing cap of the filling material, and then ensure that the leakage situation in the filling material room is normal (preferably until it leaks out).
thirteen
If the chemical pump is to be stopped for a long time, it is necessary to disassemble the pump, wipe off moisture, apply vegetable oil to the rotating position and joints, and store them properly.
fourteen
Regularly maintain the damaged condition of the coupling, and replace it immediately if it is severely damaged.