In the daily operation of Dalian Chemical Pump, we often encounter the phenomenon of the pump shaft suddenly not rotating. At this time, we can only find the cause to eliminate the fault. We can analyze it from the aspects of work, users, and process. The reason is that the multi-stage pump itself is a slender shaft, and slight matching errors in rotation, processing, or design tolerances can cause phenomena such as the inability of the multi-stage centrifugal pump shaft to rotate after starting. Next, Dalian Chemical Pump Manufacturer will share with you some reasons why the pump shaft of Dalian Chemical Pump cannot rotate, for your reference. Now please follow the editor to take a look.
1、 The production reason for the stationary rotation of the horizontal multi-stage pump shaft:
1. Firstly, the assembly of the horizontal multi-stage pump itself was caused by friction due to several parts of the pump shaft getting stuck.
2. Due to design defects and small clearances in the components of the horizontal multi-stage pump, problems were caused by single axis parts, and many components were installed after the shaft got stuck.
3. In assembly, for horizontal multi-stage pumps, if the parts need to be struck with an iron hammer or a hammer and the assembly personnel do not pay attention to using the hammer, rubber pads or copper pads need to be used to strike the area. If the rubber hammer minimizes damage to the striking parts. Because these parts are all finished components. All processed parts should be handled with care to avoid collisions.
4. The unqualified dynamic and static balance treatment of the rotor parts is caused by the friction between the entire horizontal multi-stage pump and the guide vanes, housing, etc. due to the excessive size of the rotor during high-speed rotation after installation.
2、 On site reasons for the user's inability to rotate the horizontal multi-stage pump shaft:
1. Firstly, the important reason is that a foreign object got stuck in the main impeller at the inlet of the horizontal multi-stage pump, causing the shaft to be unable to rotate.
2. The lack of oil in the bearing caused it to burn out and fix the shaft.
3. Rust on the impeller causes shaft lock.
4. The starting torque is too small, causing the shaft to not rotate.
5. Unreasonable material selection can lead to rusting and jamming of the shaft, which can damage other parts.
3、 Countermeasures and reinstallation work for shaft locking of horizontal multi-stage pump:
Secure the anchor bolts to prevent loosening. Using a high-precision level to verify the levelness of the pump and motor base, all elements meet the installation requirements, indicating that there are no issues with the installation work and no need for further grouting. Due to the locking fault of the MD type horizontal multi-stage pump shaft, it is difficult to check the alignment of the motor and pump shaft. However, the rechecked data indicates that it is within the qualified range and the alignment is good. If multi-stage pumps are started in a cold state, it is easy to cause temperature differences. Therefore, maintenance personnel should adopt a suitable pump warming plan and do sufficient pump warming work.
The reassembly work should be strictly carried out according to the reverse steps of disassembly, especially the control of dynamic and static clearances and shaft runout, which needs to be given more attention. After the reinstallation work is completed, place it in the working position, install a dial gauge at the coupling, maintain good alignment with the coupling of the motor shaft, and then tighten the anchor bolts and coupling bolts. Rotate the shaft by hand, and if there is no jamming, you can test the pump.