The heavy-duty magnetic pump has a metal lined F46 fluorine lined casing, and the entire inner and outer magnetic tiles are made of strong magnetic rare earths. Compared to the traditional heavy-duty fluoroplastic magnetic pumps, although they both use rare earth elements for both internal and external magnets in terms of materials, the old heavy-duty fluoroplastic magnetic pumps are prone to shaft breakage and other adverse phenomena when operated under abnormal working conditions, despite both using shaft transmission.
High power supply voltage: When the power supply voltage is too high, the back electromotive force, magnetic flux, and magnetic flux density of the motor all increase accordingly. Due to the fact that the magnitude of iron loss in Dalian chemical pumps is proportional to the square of magnetic flux density, the iron loss increases, leading to overheating of the iron core. And the increase in magnetic flux leads to a sharp increase in the excitation current component, causing an increase in copper loss in the stator winding and overheating of the winding.
Therefore, when the power supply voltage exceeds the rated voltage of the motor, it will cause the motor to overheat. Error in star angle connection of electric motor: When a delta connection electric motor is misconnected into a star shape, the motor still runs at full load, and the current flowing through the stator winding exceeds the rated current, even causing the motor to stop on its own. If the stop time is slightly longer and the power is not cut off, the winding will not only overheat severely, but also burn out.
When a star connected motor is misconnected into a triangle, or when several coil groups are connected in series as one branch of the motor are misconnected into two parallel branches, it will cause the winding and iron core to overheat, and in severe cases, it will burn out the winding. If the current is not stable on the spot, it can also cause the motor to heat up. When the three-phase voltages are different, that is, when one phase voltage is too high or slightly low, it can cause excessive current in a certain phase, causing the motor to overheat. Therefore, the current must exceed the required regulations. If it cannot reach the rated current, it is easy to cause the motor to operate unstably, resulting in serious heating and burning of the motor.
Before installing and starting the self-priming pump, the pump shaft should be turned and liquid should be poured into the pump chamber to fill it with liquid and reach the exhaust target. Check for any leaks in the pump and ensure that there is no friction sound or possible jamming of the impeller. If there is any friction sound or jamming, the pump should be disassembled and the detailed cause should be investigated and the fault address should be handled.